Setting for loop ejection.

Setting for loop ejection.

Setting For Loop Ejection.

This has been preset at the factory, but when the arch size is changed or IC Control Box is replaced, this needs to be reset.

Make sure strap has been loaded in the machine.

1.Turn the Tension Dial on the Operation Panel to zero.
2.Turn on the Power Switch.
3.Turn T1 timer to minimum and press START Switch to run one cycle without a package.
4.Press STOP Switch and lock it.
5.While pressing START Switch, keep the Feed/Reverse Dial twisted to the left for 3 seconds.

The Operation Ready Lamp will change from a fast blinking to a slow blinking, indicating the setting is complete.